Vision Gauges

7 Channel HMI Base Digital Gauge

7 Channel HMI base Digital air Gauge Unit

Applications Standard/Honing Dimension Type Linear Resolution 0.1μm/ 1μm Units mm Measurement Modes Current, Min, Max, TIR, AVG Additional results Max, Min, Ovality, and Taper for respective result can be display in run mode as additional results. Result Formula Editor Result formula can be edited for combinations of Piezo channels and / or other results. Indications Pass, Fail, Warning with facility to select require display reading in require colour according to the tolerance band Grade Max 25 Grades available Other Features Machine Stop Massage and Machine stop signal available for reject job condition Calibration Single/Double Master configurable / Force Mastering after N number of measured jobs / Group Calibration for selected result in one group / Auto Mastering is available. Accept Higher and Lower master on inserting into fixture/plug automatically in calibration process Auto Air Cut-Off Yes (Air will become ON after inserting job in Fixture/Plug) Air Saving facility / When nothing is inserted in Fixture/Plug Air will be OFF Measurement process Auto Cycle (After inserting job in Fixture/Plug it will show related Fixture/Plug result) / Measurement Cycle (Sequential measurement) Online SPC Cp, Cpk,

  •